Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
J Am Heart Assoc ; 13(5): e031305, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38420763

RESUMO

BACKGROUND: Preoperative kidney dysfunction is a risk factor for right heart failure (RHF) after implantation of a left ventricular assist device (LVAD). However, characteristic kidney function trajectories before and after post-LVAD RHF are uncertain, so we investigated this. METHODS AND RESULTS: We identified individuals who received primary continuous-flow LVAD implantation from July 1, 2014 to December 31, 2017 in the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) data set. Incident RHF was ascertained using the INTERMACS definition at 1 and 3 months and classified as transient or persistent. Kidney function trajectories before and after RHF onset, and relationships of baseline kidney function with RHF risk at the different time points, were assessed. We identified 8076 LVAD recipients who met inclusion criteria. Incident RHF was present at 1 month in 26.4%. There were 4850 individuals with follow-up at 3 months, with incident RHF in 4.2%. Kidney function trajectories differed from pre-LVAD implantation to 1-month follow-up by RHF category, with those developing persistent RHF having no improvement in baseline kidney function. For trajectories before the 3-month RHF ascertainment time, the shape was similar for those with and without RHF, with lower estimated glomerular filtration rate levels among those who developed RHF. Baseline estimated glomerular filtration rate levels below the normal range were associated with higher risk of RHF at 1 and 3 months. CONCLUSIONS: In LVAD recipients, preimplantation kidney function and subsequent kidney function trajectories differed substantially by RHF at 1 and 3 months postimplantation, even after adjustment for several confounders. This may demonstrate bidirectional associations between kidney function and right ventricular function in LVAD recipients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estudos Retrospectivos , Fatores de Risco , Coração Auxiliar/efeitos adversos , Rim
2.
Patient Educ Couns ; 122: 108157, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38290171

RESUMO

BACKGROUND: Personalized risk (PR) estimates may enhance clinical decision making and risk communication by providing individualized estimates of patient outcomes. We explored stakeholder attitudes toward the utility, acceptability, usefulness and best-practices for integrating PR estimates into patient education and decision making about Left Ventricular Assist Device (LVAD). METHODS AND RESULTS: As part of a 5-year multi-institutional AHRQ project, we conducted 40 interviews with stakeholders (physicians, nurse coordinators, patients, and caregivers), analyzed using Thematic Content Analysis. All stakeholder groups voiced positive views towards integrating PR in decision making. Patients, caregivers and coordinators emphasized that PR can help to better understand a patient's condition and risks, prepare mentally and logistically for likely outcomes, and meaningfully engage in decision making. Physicians felt it can improve their decision making by enhancing insight into outcomes, enhance tailored pre-emptive care, increase confidence in decisions, and reduce bias and subjectivity. All stakeholder groups also raised concerns about accuracy, representativeness and relevance of algorithms; predictive uncertainty; utility in relation to physician's expertise; potential negative reactions among patients; and overreliance. CONCLUSION: Stakeholders are optimistic about integrating PR into clinical decision making, but acceptability depends on prospectively demonstrating accuracy, relevance and evidence that benefits of PR outweigh potential negative impacts on decision making quality.


Assuntos
Coração Auxiliar , Médicos , Humanos , Tomada de Decisões , Educação de Pacientes como Assunto , Atitude
3.
ASAIO J ; 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38181411

RESUMO

We explored whether women undergo continuous-flow left ventricular assist device (CF-LVAD) implantation in later stages of heart failure (HF) than men, evidenced by worse preoperative right HF (RHF). We also compared two propensity models with and without preoperative RHF to assess its effect on outcomes. INTERMACS was queried from July 2008 to December 2017. Propensity model 1 matched men and women on age ≥50 years, HF etiology, body surface area, INTERMACS class, comorbidities, device strategy, temporary mechanical circulatory support, and device type. Model 2 included these variables plus LV end-diastolic diameter, right atrial pressure/pulmonary capillary wedge pressure, pulmonary artery pulsatility index, and right ventricular ejection fraction. The primary outcome was all-cause mortality. Secondary outcomes comprise RHF, rehospitalization, renal dysfunction, stroke, and device malfunction. In model 1, characteristics were comparable between 3,195 women and 3,195 men, except women more often had preoperative RHF and postoperative right VAD support and had worse 1 year and overall survival. In model 2, after propensity matching for additional risk factors for preoperative RHF, 1,119 women and 1,119 men had comparable post-LVAD implant RVAD use and survival. These findings suggest that women present more often with biventricular failure and after implantation have higher RHF and mortality rates.

4.
Tex Heart Inst J ; 50(4)2023 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-37624675

RESUMO

BACKGROUND: Postoperative respiratory failure is a major complication that affects up to 10% of patients who undergo cardiac surgery and has a high in-hospital mortality rate. Few studies have investigated whether patients who require tracheostomy for postoperative respiratory failure after continuous-flow left ventricular assist device (CF-LVAD) implantation have worse survival outcomes than patients who do not. OBJECTIVE: To identify risk factors for respiratory failure necessitating tracheostomy in CF-LVAD recipients and to compare survival outcomes between those who did and did not require tracheostomy. METHODS: Consecutive patients who underwent primary CF-LVAD placement at a single institution between August 1, 2002, and December 31, 2019, were retrospectively reviewed. Propensity score matching accounted for baseline differences between the tracheostomy and nontracheostomy groups. Multivariate logistic regression was used to identify tracheostomy risk factors and 90-day survival; Kaplan-Meier analysis was used to assess midterm survival. RESULTS: During the study period, 664 patients received a CF-LVAD; 106 (16.0%) underwent tracheostomy for respiratory failure. Propensity score matching produced 103 matched tracheostomy-nontracheostomy pairs. Patients who underwent tracheostomy were older (mean [SD] age, 57.9 [12.3] vs 54.6 [13.9] years; P = .02) and more likely to need preoperative mechanical circulatory support (61.3% vs 47.8%; P = .01) and preoperative intubation (27.4% vs 8.8%; P < .001); serum creatinine was higher in the tracheostomy group (mean [SD], 1.7 [1.0] vs 1.4 [0.6] mg/dL; P < .001), correlating with tracheostomy need (odds ratio, 1.76; 95% CI, 1.21-2.56; P = .003). Both before and after propensity matching, 30-day, 60-day, 90-day, and 1-year survival were worse in patients who underwent tracheostomy. Median follow-up was 0.8 years (range, 0.0-11.2 years). Three-year Kaplan-Meier survival was significantly worse for the tracheostomy group before (22.0% vs 61.0%; P < .001) and after (22.4% vs 48.3%; P < .001) matching. CONCLUSION: Given the substantially increased probability of death in patients who develop respiratory failure and need tracheostomy, those at high risk for respiratory failure should be carefully considered for CF-LVAD implantation. Comprehensive management to decrease respiratory failure before and after surgery is critical.


Assuntos
Coração Auxiliar , Procedimentos Cirúrgicos Torácicos , Humanos , Pessoa de Meia-Idade , Traqueostomia/efeitos adversos , Estudos Retrospectivos , Mortalidade Hospitalar
5.
JACC Heart Fail ; 11(5): 491-503, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36892486

RESUMO

In 2018, the United Network for Organ Sharing implemented a 6-tier allocation policy to replace the prior 3-tier system. Given increasing listings of critically ill candidates for heart transplantation and lengthening waitlist times, the new policy aimed to better stratify candidates by waitlist mortality, shorten waiting times for high priority candidates, add objective criteria for common cardiac conditions, and further broaden sharing of donor hearts. There have been significant shifts in cardiac transplantation practices and patient outcomes following the implementation of the new policy, including changes in listing practices, waitlist time and mortality, transplant donor characteristics, post-transplantation outcomes, and mechanical circulatory support use. This review aims to highlight emerging trends in United States heart transplantation practice and outcomes following the implementation of the 2018 United Network for Organ Sharing heart allocation policy and to address areas for future modification.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Obtenção de Tecidos e Órgãos , Humanos , Estados Unidos , Insuficiência Cardíaca/cirurgia , Doadores de Tecidos , Políticas , Listas de Espera , Estudos Retrospectivos
6.
ASAIO J ; 69(5): 429-437, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730653

RESUMO

Heart failure (HF) is common in adult congenital heart disease (ACHD) patients; however, use of continuous-flow ventricular assist devices (CF-VADs) remains rare. We reviewed outcomes of patients with congenital heart disease greater than or equal to 18 years of age at the time of CF-VAD implant at the affiliated pediatric and adult institutions between 2006 and 2020. In total, 18 ACHD patients (15 with great anatomical complexity) received 21 CF-VADs. Six patients (median age 34 years) received seven percutaneous CF-VADs with a median duration of support of 20 days (3-44 days) with all patients survived to hospital discharge and two patients were bridged to durable CF-VADs. Fourteen patients (median age 38 years) received durable CF-VADs. Thirteen patients (93%) survived to hospital discharge and the median duration of support was 25.8 months (6.4-52.1 months). Estimated survival on durable CF-VAD at 1, 3, and 5 years was 84%, 72%, and 36%, respectively. Three patients were successfully bridged to transplantation. Device-related complications include cerebrovascular accident (n = 5), driveline infection (n = 3), device infection requiring chronic antibiotic therapy (n = 4), gastrointestinal bleeding (n = 6), and presumed pump thrombosis (n = 5). These results show percutaneous and durable CF-VADs can support ACHD patients with advanced HF.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Criança , Humanos , Adulto , Resultado do Tratamento , Estudos Retrospectivos , Estudos Multicêntricos como Assunto
9.
J Artif Organs ; 26(4): 275-286, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36208373

RESUMO

Patients with left ventricular assist devices (LVADs) receive anticoagulation to decrease the risk of thrombosis. Various circumstances require discontinuing anticoagulation in LVAD patients, but the risks entailed are not well defined. In a retrospective review of LVAD implantation procedures, we examined the effect of time off anticoagulation on thrombosis and mortality rates after implantation. An international normalized ratio ≤ 1.5 was used to screen for patients taken off anticoagulation. Patients were divided into three groups by the cumulative number of days off anticoagulation: no discontinuation, short-term discontinuation (< 30 days), and long-term discontinuation (≥ 30 days). Rates of ischemic stroke, pump thrombosis, and mortality were compared among groups. Of 245 patients who underwent LVAD implantation during the study, 70 (28.6%) were off anticoagulation during follow-up: 37 (15.1%) had short-term discontinuation (median, 11 days), and 33 (13.5%) had long-term discontinuation (median, 124 days). Patients with long-term discontinuation had a higher rate of ischemic stroke (adjusted hazard ratio 8.5, p = 0.001) and death (adjusted hazard ratio 3.9, p = 0.001). The three groups did not differ in pump thrombosis rate. We conclude that after LVAD implantation, discontinuing anticoagulation for ≥ 30 days is independently associated with an increased risk of ischemic stroke and death.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , AVC Isquêmico , Trombose , Humanos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/complicações , Trombose/etiologia , Trombose/prevenção & controle , Estudos Retrospectivos , Anticoagulantes/uso terapêutico , AVC Isquêmico/induzido quimicamente , AVC Isquêmico/complicações , Resultado do Tratamento
10.
J Heart Lung Transplant ; 41(12): 1798-1807, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36182652

RESUMO

BACKGROUND: The aim of this study was to assess for distinct kidney function trajectories following left ventricular assist device (LVAD) placement. Cohort studies of LVAD recipients demonstrate that kidney function tends to increase early after LVAD placement, followed by decline and limited sustained improvement. Inter-individual differences in kidney function response may be obscured. METHODS: We identified continuous flow LVAD implantations in US adults (2016-2017) from INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support). Primary outcomes were estimated glomerular filtration rate (eGFR) trajectories pre-implantation to ∼12 months. Latent class mixed models were applied to primary and validation samples. Clinical differences among trajectory groups were investigated. RESULTS: Among 4,615 LVAD implantations, 5 eGFR trajectory groups were identified. The 2 largest groups (Groups 1 and 2) made up >80% of the cohort, and were similar to group average trajectories previously reported, with early eGFR rise followed by decline and stabilization. Three novel trajectory groups were found: worsening followed by sustained low kidney function (Group 3, 10.1%), sustained improvement (Group 4, 3.3%), and worsening followed by variation (Group 5, 1.7%). These groups differed in baseline characteristics and outcomes. Group 4 was younger and had more cardiogenic shock and pre-implantation dialysis; Group 3 had higher rates of pre-existing chronic kidney disease, along with older age. CONCLUSIONS: Novel eGFR trajectories were identified in a national cohort, possibly representing distinct cardiorenal processes. Type 1 cardiorenal syndrome may have been predominant in Group 4, and parenchymal kidney disease may have been predominant in Group 3.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Humanos , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento , Sistema de Registros , Rim , Estudos Retrospectivos
11.
Curr Probl Cardiol ; 47(11): 101303, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35787427

RESUMO

Cardiogenic shock (CS) is the final common pathway of impaired cardiovascular performance that results in ineffective forward cardiac output producing clinical and biochemical signs of organ hypoperfusion. CS represents the most common cause of shock in the cardiac intensive care unit (CICU) and accounts for a substantial proportion of CICU patient deaths. Despite significant advances in revascularization techniques, pharmacologic therapeutics and mechanical support devices, CS remains associated with a high mortality rate. Indeed, the prevalence of CS within the CICU appears to be increasing. CS can be differentiated as phenotypes reflecting different metabolic, inflammatory, and hemodynamic profiles, depending also on anatomic substrate and congestion profile. Future prospective studies and clinical trials may further characterize these phenotypes and apply targeted intervention for each phenotype and SCAI SHOCK stage rather than a one-size-fits-all approach. Overall, there are 8 key concepts of CS; 1) the mortality associated with CS; 2) Shock attributed to AMI may be declining in both incidence and associated mortality; 3) providers should think about hemodynamic, metabolic, inflammation and cardiac function in totality to assess CS; 4) CS is a dynamic process; 5) no randomized trials evaluating use of the PAC in patients with CS; 6) most data supporting neosynephrine as first line agent in CS; 7) most registries suggest that almost half of CS patients do not have any mechanical support, and the vast majority of the remainder utilize the IABP; and 8) patients with AMI CS should receive emergent PCI of the culprit vessel.


Assuntos
Intervenção Coronária Percutânea , Choque Cardiogênico , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fenilefrina , Estudos Prospectivos , Sistema de Registros , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/etiologia , Resultado do Tratamento
12.
Artif Organs ; 46(9): 1923-1931, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35524483

RESUMO

BACKGROUND: Hyponatremia is associated with adverse outcomes in heart failure and after cardiac surgery. We hypothesized that hyponatremia is associated with poorer short-term and longer term survival in patients after continuous-flow left ventricular assist device (CF-LVAD) placement. METHODS: We reviewed a single-center database of patients who received a CF-LVAD during 2012-2017. Sodium (Na) values obtained within 14 days before CF-LVAD insertion were averaged; patients (n = 332) were divided into hyponatremia (mean Na <135 mEq/L; n = 160; 48.2%) and normonatremia groups (mean Na 135-145 mEq/L; n = 172; 51.8%). Patients requiring preoperative dialysis or pump exchange were excluded. We compared outcomes between preoperative hyponatremia and normonatremia groups. RESULTS: The two groups' baseline characteristics were similar, although hyponatremia patients more often had preoperative mechanical circulatory support (44.4% vs. 31.4%, p = 0.002). Although hyponatremic and normonatremic patients did not differ in 30-day mortality (7.5% vs. 6.5%, p = 0.7), preoperative hyponatremia was associated with greater 5-year mortality (61% vs. 44%, p = 0.03). On binary logistic regression analysis, the strongest independent predictors of late mortality were hyponatremia (odds ratio [OR] 1.88, 95% CI [1.07-3.31], p = 0.02), older age (OR 1.03, 95% CI [1.01-1.05], p = 0.01), and elevated mean right atrial pressure/pulmonary capillary wedge pressure ratio (OR 4.69, 95% CI [1.76-12.47], p = 0.002). CONCLUSIONS: Hyponatremia was not associated with greater early mortality but was associated with poorer late survival. The optimal timing of LVAD implantation in relation to hyponatremia, and whether correcting hyponatremia perioperatively improves long-term survival, should be investigated.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Coração Auxiliar , Hiponatremia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Hiponatremia/epidemiologia , Análise de Sobrevida , Resultado do Tratamento
13.
Kidney360 ; 3(3): 569-579, 2022 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-35582171

RESUMO

Durable and temporary mechanical circulatory support (MCS) use is growing for a range of cardiovascular indications. Kidney dysfunction is common in people evaluated for or receiving durable or temporary MCS and portends worse outcomes. This kidney dysfunction can be due to preexisting kidney chronic kidney disease (CKD), acute kidney injury (AKI) related to acute cardiovascular disease necessitating MCS, AKI due to cardiac procedures, and acute and chronic MCS effects and complications. Durable MCS, with implantable continuous flow pumps, is used for long-term support in advanced heart failure refractory to guideline-directed medical and device therapy, either permanently or as a bridge to heart transplantation. Temporary MCS-encompassing in this review intra-aortic balloon pumps (IABP), axial flow pumps, centrifugal flow pumps, and venoarterial ECMO-is used for diverse situations: high-risk percutaneous coronary interventions (PCI), acute decompensated heart failure, cardiogenic shock, and resuscitation after cardiac arrest. The wide adoption of MCS makes it imperative to improve understanding of the effects of MCS on kidney health/function and of kidney health/function on MCS outcomes. The complex structure and functions of the kidney, and the complex health states of individuals receiving MCS, makes investigations in this area challenging, and current knowledge is limited. Fortunately, the increasing nephrology toolbox of noninvasive kidney health/function assessments may enable development and testing of individualized management strategies and therapeutics in the future. We review technology, epidemiology, pathophysiology, clinical considerations, and future directions in MCS and nephrology.


Assuntos
Injúria Renal Aguda , Insuficiência Cardíaca , Nefrologia , Intervenção Coronária Percutânea , Injúria Renal Aguda/terapia , Insuficiência Cardíaca/terapia , Humanos , Balão Intra-Aórtico
14.
J Artif Organs ; 25(1): 16-23, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33982206

RESUMO

Left ventricular assist devices (LVADs) are increasingly used as destination therapy or as a bridge to future cardiac transplant in patients with end-stage heart failure. Extracorporeal membrane oxygenation (ECMO) can be used to bridge patients in cardiogenic shock or with decompensated heart failure to durable mechanical circulatory support. We assessed outcomes in patients in critical cardiogenic shock (Interagency Registry for Mechanically Assisted Circulatory Support [INTERMACS] profile 1) who underwent implantation of a continuous-flow (CF)-LVAD, with or without preoperative ECMO bridging. For this retrospective study, we selected INTERMACS profile 1 patients who underwent CF-LVAD implantation at our institution between Sep 1, 2004 and Nov 30, 2018. Of 768 patients identified, 133 (17.3%) were INTERMACS profile 1; 26 (19.5%) received preoperative ECMO support, and 107 (80.5%) did not. Postimplantation outcomes were compared between the ECMO and no-ECMO groups. No significant differences were found in 30-day mortality (15.4 vs. 15.9%, P = 0.95) or survival at 1 year (53.8 vs. 60.9%, P = 0.51). Three patients who received ECMO before CF-LVAD implantation subsequently underwent cardiac transplant. In the ECMO group, the lactate level 1 day after ECMO initiation was lower in survivors than nonsurvivors (2.7 ± 2.2 vs. 7.4 ± 4.2 mmol/L, P = 0.02; area under the curve = 0.85, P = 0.01) after CF-LVAD implantation. Bridging with ECMO to CF-LVAD implantation in carefully selected INTERMACS profile 1 patients (those who are at the highest risk for critical cardiogenic shock and for whom palliation may be the only other option) produced acceptable postoperative outcomes.Field of research: Artificial lung/ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/cirurgia , Humanos , Sistema de Registros , Estudos Retrospectivos , Choque Cardiogênico/cirurgia , Resultado do Tratamento
15.
J Card Fail ; 28(8): 1326-1336, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34936896

RESUMO

Venoarterial extracorporeal life support (VA-ECLS) is a powerful tool that can provide complete cardiopulmonary support for patients with refractory cardiogenic shock. However, VA-ECLS increases left ventricular (LV) afterload, resulting in greater myocardial oxygen demand, which can impair myocardial recovery and worsen pulmonary edema. These complications can be ameliorated by various LV venting strategies to unload the LV. Evidence suggests that LV venting improves outcomes in VA-ECLS, but there is a paucity of randomized trials to help guide optimal strategy and the timing of venting. In this review, we discuss the available evidence regarding LV venting in VA-ECLS, explain important hemodynamic principles involved, and propose a practical approach to LV venting in VA-ECLS.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Hemodinâmica , Humanos , Choque Cardiogênico/terapia
16.
Interact Cardiovasc Thorac Surg ; 34(3): 470-477, 2022 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-34966937

RESUMO

OBJECTIVES: Dialysis is considered a contraindication to continuous-flow left ventricular assist device (CF-LVAD) implantation. We evaluated clinical outcomes and survival in carefully selected, low-risk patients with renal failure who required dialysis before CF-LVAD implantation. METHODS: We extracted medical record data of patients who underwent CF-LVAD placement at our centre between 1 January 2006 and 31 August 2017, with 2 clinical scenarios: those who required long-term (>14 days) dialysis and those who required short-term (≤14 days) dialysis immediately before implantation. Demographic, clinical and intraoperative characteristics and survival outcomes were assessed. RESULTS: Of 621 patients who underwent CF-LVAD implantation during the study period, 31 underwent dialysis beforehand. Of these, 17 required long-term dialysis (13 haemodialysis, 4 peritoneal dialysis), and 14 underwent short-term haemodialysis. Compared with the long-term dialysis patients, the short-term dialysis patients were more likely to be Interagency Registry for Mechanically Assisted Circulatory Support profile 1-2 (92.9% vs 70.6%; P < 0.001), to have needed preoperative mechanical circulatory support (78.6% vs 70.6%; P < 0.01) and to have higher in-hospital mortality (85.7% vs 29.4%; P = 0.01). Patients stable on long-term dialysis had acceptable overall survival and markedly better 6-month and 1-year survival than those with short-term dialysis before implantation (64.7% vs 14.3% and 58.8% vs 7.1%, respectively; P < 0.001). CONCLUSIONS: Carefully selected patients who are stable on long-term dialysis have acceptable survival rates after CF-LVAD implantation. Patients with acute renal failure had much poorer outcomes than those with chronic end-stage renal disease.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Tex Heart Inst J ; 48(4)2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34468765

RESUMO

To determine whether the cause of cardiomyopathy affects outcomes in patients who undergo continuous-flow left ventricular assist device support, we compared postimplant adverse events and survival between patients with ischemic and nonischemic cardiomyopathy. The inclusion criteria for the ischemic group were a history of myocardial infarction or revascularization (coronary artery bypass grafting or percutaneous coronary intervention), ≥75% stenosis of the left main or proximal left anterior descending coronary artery, or ≥75% stenosis of ≥2 epicardial vessels. From November 2003 through March 2016, 526 patients underwent device support: 256 (48.7%) in the ischemic group and 270 (51.3%) in the nonischemic group. The ischemic group was older (60.0 vs 50.0 yr), included more men than women (84.0% vs 72.6%), and had more comorbidities. More patients in the nonischemic group were able to have their devices explanted after left ventricular recovery (5.9% vs 2.0%; P=0.02). More patients in the ischemic group had gastrointestinal bleeding (31.2% vs 22.6%; P=0.03), particularly from arteriovenous malformations (20.7% vs 11.9%; P=0.006) and ulcers (16.4% vs 9.3%; P=0.01). Kaplan-Meier analysis revealed no difference in overall survival between groups (P=0.24). Older age, previous sternotomy, higher total bilirubin level, and concomitant procedures during device implantation independently predicted death (P ≤0.03), whereas cause of heart failure did not (P=0.08). Despite the similarity in overall survival between groups, ischemic cardiomyopathy was associated with more frequent gastrointestinal bleeding. This information may help guide the care of patients with ischemic cardiomyopathy who receive continuous-flow left ventricular assist device support.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Coração Auxiliar , Isquemia Miocárdica , Idoso , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Masculino , Isquemia Miocárdica/complicações , Isquemia Miocárdica/terapia , Estudos Retrospectivos , Resultado do Tratamento
18.
Genet Med ; 23(12): 2404-2414, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34363016

RESUMO

PURPOSE: Cardiovascular disease (CVD) is the leading cause of death in adults in the United States, yet the benefits of genetic testing are not universally accepted. METHODS: We developed the "HeartCare" panel of genes associated with CVD, evaluating high-penetrance Mendelian conditions, coronary artery disease (CAD) polygenic risk, LPA gene polymorphisms, and specific pharmacogenetic (PGx) variants. We enrolled 709 individuals from cardiology clinics at Baylor College of Medicine, and samples were analyzed in a CAP/CLIA-certified laboratory. Results were returned to the ordering physician and uploaded to the electronic medical record. RESULTS: Notably, 32% of patients had a genetic finding with clinical management implications, even after excluding PGx results, including 9% who were molecularly diagnosed with a Mendelian condition. Among surveyed physicians, 84% reported medical management changes based on these results, including specialist referrals, cardiac tests, and medication changes. LPA polymorphisms and high polygenic risk of CAD were found in 20% and 9% of patients, respectively, leading to diet, lifestyle, and other changes. Warfarin and simvastatin pharmacogenetic variants were present in roughly half of the cohort. CONCLUSION: Our results support the use of genetic information in routine cardiovascular health management and provide a roadmap for accompanying research.


Assuntos
Cardiologia , Doenças Cardiovasculares , Adulto , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/genética , Doenças Cardiovasculares/terapia , Testes Genéticos , Humanos , Farmacogenética/métodos , Testes Farmacogenômicos , Estados Unidos
19.
Tex Heart Inst J ; 48(2)2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34111275

RESUMO

Continuous-flow left ventricular assist devices have proved to be effective, durable, life-saving tools in patients with end-stage heart failure. However, because of the risks associated with mechanical circulatory support (including stroke, infection, gastrointestinal bleeding, and device malfunction), the optimal goal of device therapy is myocardial recovery and device removal. Ventricular reconditioning and pump explantation after continuous-flow support have been reported; however, little is known about variables that govern the pace and degree of myocardial response in patients who experience such recovery. We describe our long-term pump-weaning strategy for a 25-year-old man who had a continuous-flow device implanted and then needed more than 5 years of support from it before developing cardiac reserve sufficient to enable pump explantation. To our knowledge, this is the longest period of uninterrupted continuous-flow device support to end in successful pump deactivation and a return to medical therapy. This case highlights the importance of actively and persistently pursuing a device-weaning strategy in all patients who need left ventricular assist device therapy.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Remoção de Dispositivo , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Resultado do Tratamento
20.
BMC Med Inform Decis Mak ; 21(1): 106, 2021 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-33743685

RESUMO

BACKGROUND: A central goal among researchers and policy makers seeking to implement clinical interventions is to identify key facilitators and barriers that contribute to implementation success. Despite calls from a number of scholars, empirical insights into the complex structural and cultural predictors of why decision aids (DAs) become routinely embedded in health care settings remains limited and highly variable across implementation contexts. METHODS: We examined associations between "reach", a widely used indicator (from the RE-AIM model) of implementation success, and multi-level site characteristics of nine LVAD clinics engaged over 18 months in implementation and dissemination of a decision aid for left ventricular assist device (LVAD) treatment. Based on data collected from nurse coordinators, we explored factors at the level of the organization (e.g. patient volume), patient population (e.g. health literacy; average sickness level), clinician characteristics (e.g. attitudes towards decision aid; readiness for change) and process (how the aid was administered). We generated descriptive statistics for each site and calculated zero-order correlations (Pearson's r) between all multi-level site variables including cumulative reach at 12 months and 18 months for all sites. We used principal components analysis (PCA) to examine any latent factors governing relationships between and among all site characteristics, including reach. RESULTS: We observed strongest inclines in reach of our decision aid across the first year, with uptake fluctuating over the second year. Average reach across sites was 63% (s.d. = 19.56) at 12 months and 66% (s.d. = 19.39) at 18 months. Our PCA revealed that site characteristics positively associated with reach on two distinct dimensions, including a first dimension reflecting greater organizational infrastructure and standardization (characteristic of larger, more established clinics) and a second dimension reflecting positive attitudinal orientations, specifically, openness and capacity to give and receive decision support among coordinators and patients. CONCLUSIONS: Successful implementation plans should incorporate specific efforts to promote supportive and mutually informative interactions between clinical staff members and to institute systematic and standardized protocols to enhance the availability, convenience and salience of intervention tool in routine practice. Further research is needed to understand whether "core predictors" of success vary across different intervention types.


Assuntos
Letramento em Saúde , Coração Auxiliar , Humanos , Motivação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA